Skip to content

Shelly Plus PM Mini

Device identification

  • Device name: Shelly Plus PM Mini
  • Device model: SNPM-001PCEU16
  • Device SSID: ShellyPMMini-XXXXXX

Short description

Shelly Plus PM Mini (The Device) is a small form factor power meter. Enhanced with all the gen2 firmware flexibility, it provides professional integrators with additional options for end-customer solutions. It can work standalone in a local Wi-Fi network, or it can also be operated through cloud home automation services through MQTT, HTTP, and WebSocket. All inbound connections support TLS.

Shelly Plus PM Mini can be accessed, set up, and monitored remotely by the User, as well as the Device can access and communicate with an automation system, as long as they are in the same network infrastructure.

The Device has an embedded Web Interface which can be used to monitor and control the device, as well as adjust its settings.

NOTICE! The Device does not have a built-in relay.

Main applications

  • Residential
  • MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
  • Light commercial (small office buildings, small retail/restaurant/gas station, etc.)

Simplified internal schematics

Shelly Plus PM Mini internal schematics

Device electrical interfaces

Inputs

  • 2 line inputs on screw terminals: 1 L and 1 N

Outputs

  • 2 load circuit outputs (bridged internally): 2 O

Connectivity

  • Wi-Fi
  • Bluetooth (for inclusion purposes)

Each connectivity option can be enabled or disabled by the user.

Safety features

  • Internal temperature sensing and reporting

Supported load types

  • Resistive (incandescent bulbs, heating devices)
  • Capacitive (LED light drivers, capacitor banks, electronic equipment, motor start capacitors)
  • Inductive (transformers, fans, refrigerators, air-conditioners)

User interface

Inputs

  • One (Reset) button
    • Press and hold for 5 seconds to enable Device access point and Bluetooth connection.
    • Press and hold for 10 seconds to factory reset the Device.

Outputs

  • LED (monocolor) indication
    • AP (Access Point) enabled and Wi-Fi disabled: 1 second ON / 1 second OFF
    • Wi-Fi enabled, but not connected to a Wi-Fi network: 1 second ON / 3 seconds OFF
    • Connected to a Wi-Fi network: Constantly ON
    • Cloud is enabled, but not connected: 1 second ON / 5 seconds OFF
    • Connected to Shelly Cloud: Constantly ON
    • OTA (Over the Air Update): ½ sec ON / ½ sec OFF
    • Button pressed and held for 5 seconds: ½ sec ON / ½ sec OFF
    • Button pressed and held for 10 seconds: ¼ sec ON / ¼ sec OFF

The list above starts with the initial device status and the lowest priority. Every next state cancels the previous one.

Specifications

TypeValue
Physical
Size (HxWxD)29 x 35 x 16 ±0.5 mm / 1.11 x 1.35 x 0.63 ±0.02 in
Weight13 ±1 g / 0.46 ±0.04 oz
MountingWall box
Screw terminals max torque0.4 Nm / 3.5 lbin
Conductor cross section0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length5 to 6 mm / 0.20 to 0.24 in
Shell materialPlastic
ColorLight gray
Environmental
Ambient temperature-20 °C to 40 °C / -5 °F to 105 °F
Humidity30 % to 70 % RH
Max. altitude2000 m / 6562 ft
Electrical
Power supply110 - 240 VAC
External protection16 A, tripping characteristic B or C, 6 kA interrupting rating, Energy limiting class 3
Power consumption<1.2 W
Output circuits ratings
Max measurement voltage240 VAC
Max measurement current16 A
Max measurement power3840 W
Power measurementYes
Voltage protection / CutoffNo
Current protection / CutoffNo
Max power protection / CutoffNo
Radio
RF band2400 - 2495 MHz
Max. RF power<20 dBm
Wi-Fi protocol802.11 b/g/n
Wi-Fi RangeUp to 30 m / 100 ft indoors and 50 m / 160 ft outdoors
(Depends on local conditions)
Bluetooth Protocol4.2
Bluetooth RangeUp to 10 m / 33 ft indoors and 30 m / 100 ft outdoors
(Depends on local conditions)
MCU
CPUESP32
Flash4 MB
Firmware capabilities
Webhooks (URL actions)20 with 5 URLs per hook
ScriptingYes
MQTTYes
UDPYes

Basic wiring diagrams

Plus-PM-Mini-wiring-diagram-20240528-142223

Legend

TerminalsDescriptionWiresDescription
OLoad circuit output terminals (bridged internally)LLive (110-240 V) wire
LLive (110-240 V) terminalNNeutral wire
NNeutral terminal

Troubleshooting

Your device is overheating

Make sure the ambient temperature does not exceed 40 °C / 105 °F. If placed in a confined space, Shelly Plus PM Mini may increase the ambient temperature above the allowed limits. Ensure ventilation of the device.

Web Interface guide

Read the Shelly Plus PM Mini web interface guide:

Printed user guide

Shelly Plus PM Mini multilingual printed user and safety guide

Compliance

Compliance archive

Installation guides

There are no items with the selected labels at this time.