Shelly Wave 1 Mini (EU)
Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

Device Identification
- Device name: Wave 1 Mini
- EU Part number / Ordering Code: QMSW-0A1X8EU
- Z-Wave Product type ID: 0x0002
- Z-Wave Product ID: 0x008E
- Z-Wave Manufacturer: Shelly Europe Ltd.
- Z-Wave Manufacturer ID: 0x0460
Terminology
- Device – In this document, the term “Device” refers to the Shelly Qubino device that is the subject of this guide.
- Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
- S button – The Z-Wave® Service button, located on Z-Wave® devices and used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
Short Description
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state — on, off, on, etc. If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button will change the output O (O1) state to the opposite state — on, off, on, etc.
Switch Connected to Input Terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state — on, off, on, etc.
- Change switch position once: Change the state of the output O (O1) to the opposite state and send the command to associated devices in groups 2 and 3 (see Z-Wave Association).
Switch-Memory Connected to Input Terminal SW (SW1)
If the SW (SW1) is configured as a switch-memory:
- Switching to Close switch-memory contact: Change the output state O (O1) to the On state and send a command to associated devices in groups 2 and 3 (see Z-Wave Association).
- Switching to Open switch-memory contact: Change the output state O (O1) to the Off state and send a command to associated devices in groups 2 and 3 (see Z-Wave Association).
Push-Button Connected to Input Terminal SW (SW1)
If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button changes the output state O (O1) to the opposite — ON, OFF, ON, etc.
- 1x click: Change the state of the output O (O1) to the opposite one and send a command to associated devices in groups 2 and 3 (see Z-Wave Association).
- 2x click: If the delay between the first and second click is less than 500ms, it is interpreted as a double click. Send a command to associated devices (dimmers, shutters, etc.) in groups 2 and 3 (see Z-Wave Association).
- Hold: Send a command to associated devices in group 3 (see Z-Wave Association).
- Release: Send a command to associated devices in group 3 (see Z-Wave Association).
Main Applications
- Residential
- MDU (Multi Dwelling Units – apartments, condominiums, hotels, etc.)
- Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
- Government/municipal
- University/college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave. This means Shelly Qubino Wave works with all certified gateways supporting the Z-Wave communication protocol.
To ensure full functionality, we regularly perform compatibility tests with different Z-Wave gateways.
Simplified Internal Schematics

Device Electrical Interfaces
Inputs
- 1 switch/button input on screw terminal
- 1 potential-free contact relay input on screw terminal
- 2 power supply inputs on screw terminals: N, L
Outputs
- 1 potential-free contact relay output on screw terminal
Addon Interface
N/A
Connectivity
Z-Wave – Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety Features
Overheat Protection
- Switches off its own relay
- Sends a Notification Report to the Gateway (Overheat detected)
- LED lights react as specified (check blinking mode for Overheat detected)
Any of the following activities reset this alarm:
- Power cycle
- Short press on S button
- Press any switch/push-button connected to any SW (SW, SW1, SW2, …) terminal
NOTE: The Overheat protection is always active and cannot be disabled.
Additional description available under Notification for Overheat Detected.
Supported Load Types
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User Interface
S Button and Operating Modes
- Normal mode
- Setting in progress mode
- Setting mode (with S button)
- Settings mode is required to start procedures like adding (inclusion), removing (exclusion), or factory reset. It has a limited time window. After completion, the device automatically returns to Normal mode.
- Entering Setting mode:
- Quickly press and hold the S button until the LED turns solid blue.
- An additional quick press changes the menu in an infinite loop.
- Menu LED status has a 10-second timeout before returning to Normal state.
S Button’s Functions
- Manually add the device to a Z-Wave network
- Manually remove the device from a Z-Wave network
- Factory reset the device
LED Signalisation
Normal Mode
Removed/Excluded: LED blinks blue in Mode 1 for 10 minutes after every power cycle and after pressing the S button.

Added/Included: LED blinks green in Mode 1 for 10 minutes after every power cycle and after pressing the S button.

Settings in Progress
- Factory reset and reboot: During reset, LED turns solid green (~1 sec), then blue and red blink alternately (0.1s On / 0.1s Off) for ~2 seconds.
- Adding / Removing: LED blinks blue in Mode 2.

- Firmware updating OTA: LED blinks blue and red in Mode 2.

- Checking power supply (230 V AC frequency or 24 V DC voltage): LED blinks blue and red in Mode 5.

Settings Mode with S Button
- Adding / Removing menu selected: LED stays solid blue for up to 10 seconds.
- Adding / Removing process selected: LED blinks blue in Mode 3.

- Factory reset menu selected: LED stays solid red for up to 10 seconds.
- Factory reset process selected: LED blinks red in Mode 3.

Alarm Mode
- Overheat detected: LED blinks red in Mode 4 — 0.2s On / 0.2s Off repeated in sequence (0.2s On / 0.2s Off × 1–6 + 2s Off).

LED Blinking Modes
| Mode | Blink Pattern |
|---|---|
| Mode 1 | 0.5s On / 2s Off |
| Mode 2 | 0.5s On / 0.5s Off |
| Mode 3 | 0.1s On / 0.1s Off |
| Mode 4 | (1–6 times) 0.2s On / 0.2s Off + 2s Off |
| Mode 5 | 0.2s On (blue) / 0.2s On (red) |
Specifications
| Parameter | Value |
|---|---|
| Power supply | 110 – 240 V AC, 50/60 Hz |
| Power consumption | < 0.3 W |
| Max. switching voltage AC | 240 V |
| Max. switching current AC | 8 A |
| Max. switching power AC | 2000 W |
| Max. switching voltage DC | 30 V |
| Max. switching current DC | 5 A |
| Overheating protection | Yes |
| Distance | Up to 40 m indoors (131 ft.) – depends on local conditions |
| Z-Wave® repeater | Yes |
| CPU | Z-Wave® S800 |
| Z-Wave® frequency band | 868.4 MHz |
| Max. radio frequency power transmitted | < 25 mW |
| Size (H x W x D) | 29 × 35 × 16 ±0.5 mm / 1.11 × 1.35 × 0.63 ±0.02 in |
| Weight | 19 ±1 g / 0.65 ±0.04 oz |
| Mounting | Wall box |
| Screw terminals max. torque | 0.4 Nm / 3.54 lbin |
| Conductor cross section | 0.5 to 1.5 mm² / 20 to 16 AWG |
| Conductor stripped length | 5 to 6 mm / 0.20 to 0.24 in |
| Shell material | Plastic |
| Color | Blue |
| Ambient temperature | -20°C to 40°C / -5°F to 105°F |
| Humidity | 30% to 70% RH |
| Max. altitude | 2000 m / 6562 ft. |
Basic Wiring Diagram


Legend
| Terminals | Description | Cables | Description |
|---|---|---|---|
| N | Neutral terminal | N | Neutral wire |
| L | Live terminal (110–240 V AC) | L | Live (110–240 VAC) wire |
| SW | Switch/push-button input terminal (controlling O) | — | — |
| I | Load circuit input terminal | S | S button |
| O | Load circuit output terminal | — | — |
About Z-Wave®
Adding the Device to a Z-Wave® Network (Inclusion)
Note! All device outputs (O, O1, O2, etc.) will briefly turn on/off if the device is successfully added/removed.
Note! For Security 2 (S2) inclusion, a dialog will prompt you to enter the 5-digit PIN code printed on the Z-Wave® DSK label on the device and in the packaging.
IMPORTANT: Do not lose the PIN code.
SmartStart Inclusion
SmartStart-enabled products can be added by scanning the Z-Wave® QR code on the device using a gateway with SmartStart support. No further action needed — automatic addition within 10 minutes of powering on.
- Scan the QR code on the device label via the gateway app and add the DSK to the provisioning list.
- Connect the device to power.
- Check if the blue LED is blinking in Mode 1 → indicates not added.
- Addition starts automatically within seconds after power-up.
- Blue LED blinks in Mode 2 during inclusion.
- Green LED blinks in Mode 1 upon successful addition.
Adding with S Button
- Connect device to power.
- Confirm blue LED blinks in Mode 1 → not added.
- Enable add/remove mode on the gateway.
- Press and hold S button until LED turns solid blue (entering Setting mode).
- Release quickly, then press and hold (>2s) until blue LED blinks in Mode 3 → Learn mode starts.
- Blue LED blinks in Mode 2 during addition.
- Green LED blinks in Mode 1 if successful.
Note: Setting mode has a 10-second timeout before returning to Normal mode.
Adding with a Switch/Push-Button
- Connect device to power.
- Confirm blue LED blinks in Mode 1 → not added.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button connected to any SW terminal (SW, SW1, etc.) 3 times within 3 seconds → enters Learn mode.
- Blue LED blinks in Mode 2 during addition.
- Green LED blinks in Mode 1 upon success.
Learn mode: A state allowing the device to receive network information from the gateway.
Removing the Device from a Z-Wave® Network (Exclusion)
Note: Removal does not erase custom configurations.
Note! All device outputs will briefly turn on/off during removal.
Removing with S Button
- Connect device to power.
- Confirm green LED blinks in Mode 1 → added.
- Enable add/remove mode on the gateway.
- Press and hold S button until LED turns solid blue.
- Release quickly, then press and hold (>2s) until blue LED blinks in Mode 3 → LEARN MODE starts.
- Blue LED blinks in Mode 2 during removal.
- Blue LED blinks in Mode 1 upon successful removal.
Note: Setting mode has a 10-second timeout.
Removing with Switch/Push-Button
- Connect device to power.
- Confirm green LED blinks in Mode 1 → added.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button 3 times within 3 seconds → enters LEARN MODE.
- Blue LED blinks in Mode 2 during removal.
- Blue LED blinks in Mode 1 upon success.
Factory Reset
General
After factory reset, all custom parameters (kWh, associations, routings, etc.) revert to default. HOME ID and NODE ID are deleted. Use only when the gateway is missing or inoperable.
With S Button
Note: Can be done anytime.
- Press and hold S button until LED turns solid blue (enter Setting mode).
- Press S button repeatedly until LED turns solid red.
- Hold S button (>2s) until red LED starts blinking in Mode 3 → factory reset begins.
- During reset: LED turns solid green (~1s), then blue and red blink in Mode 3 (~2s).
- Blue LED blinks in Mode 1 if successful.
With Switch/Push-Button
Note: Only possible within the first minute after power-up.
- Connect device to power.
- Toggle the switch/push-button 5 times within 3 seconds → triggers reset.
- During reset: LED turns solid green (~1s), then blue and red blink in Mode 3 (~2s).
- Blue LED blinks in Mode 1 if successful.
Remotely via Parameter
Factory reset can be triggered remotely by setting Parameter No. 120 to 1.
Z-Wave® Security and Device Specific Key (DSK)
The device supports Security 2 (S2) using Strong AES-128 encryption — making Z-Wave® the most secure IoT platform.
- Authenticated Control
- Out-of-band DSK for inclusion
- Compatible with most implementations
The device supports S2 Authenticated, Unauthenticated, and Unsecure inclusion.
Note: When adding via S2-enabled gateway, the 5-digit PIN from the DSK label is required. The DSK label is on the side of the device and inside the packaging. Do not remove it. Use the backup copy.

The first five digits are highlighted/underlined for easy identification. The DSK is also represented via QR code.
Obfuscation: Joining nodes obfuscate their public key by setting bytes 1–2 to zero (0x00) before RF transfer.
DSK Usage: May be used for out-of-band (OOB) authentication. The gateway can scan the QR code to match the obfuscated public key received via RF.
Z-Wave® Parameters
Parameter No. 1 – SW (SW1) Switch Type
Defines how the device treats the switch connected to SW (SW1).
- Size: 1 Byte
- Default: 2
- Values:
- 0: Momentary switch
- 1: Toggle switch (contact closed = ON / open = OFF)
- 2: Toggle switch (device changes status when switch changes)
Parameter No. 17 – Restore State of O (O1) After Power Failure
Determines whether the last ON/OFF state is restored after power failure.
- Size: 1 Byte
- Default: 0
- Values:
- 0: Save and restore last state
- 1: Do not save; remains OFF
Parameter No. 19 – O (O1) Auto OFF with Timer
Schedule auto-off after defined time. Timer resets on every ON command (remote or local).
- Size: 2 Bytes
- Default: 0
- Values:
- 0: Auto OFF disabled
- 1–32535: Seconds (or milliseconds — see Parameter 25)
Parameter No. 20 – O (O1) Auto ON with Timer
Schedule auto-on after defined time. Timer resets on every OFF command.
- Size: 2 Bytes
- Default: 0
- Values:
- 0: Auto ON disabled
- 1–32535: Seconds (or milliseconds — see Parameter 25)
Parameter No. 23 – O (O1) Contact Type – NO/NC
Sets relay contact type: Normally Open (NO) or Normally Closed (NC).
- Size: 1 Byte
- Default: 0
- Values:
- 0: NO
- 1: NC
| par-NO/NC | Command | Output State |
|---|---|---|
| NO (0) | OFF | OFF (0 V) |
| NO (0) | ON | ON (230 V) |
| NC (1) | OFF | ON (230 V) |
| NC (1) | ON | OFF (0 V) |
Parameter No. 25 – Set Timer Units to s or ms for O (O1)
Choose timer resolution: seconds or milliseconds.
- Size: 1 Byte
- Default: 0
- Values:
- 0: Seconds
- 1: Milliseconds
Parameter No. 91 – Water Alarm
Determines response to water alarm frames.
- Size: 4 Bytes
- Default: 0
- Values:
- 0: No action
- 1: Open relay
- 2: Close relay
Parameter No. 92 – Smoke Alarm
Same as above for smoke alarms.
- Default: 0
- Values: 0 (no action), 1 (open), 2 (close)
Parameter No. 93 – CO Alarm
Same for carbon monoxide alarms.
- Default: 0
- Values: 0 (no action), 1 (open), 2 (close)
Parameter No. 94 – Heat Alarm
Same for heat alarms.
- Default: 0
- Values: 0 (no action), 1 (open), 2 (close)
Parameter No. 120 – Factory Reset
Resets device to factory defaults and removes from Z-Wave network.
- Size: 1 Byte
- Default: 0
- Values:
- 0: Do not reset
- 1: Perform factory reset
Advanced parameter; may be hidden under "Advanced" tab.
Parameter No. 201 – Serial Number 1
Part of device serial number. Read-only. Advanced.
- Size: 4 Bytes
- Value range: 0x00000000 – 0x7FFFFFFF
Parameter No. 202 – Serial Number 2
Same as above.
Parameter No. 203 – Serial Number 3
Same as above.
Z-Wave® Command Classes
- ASSOCIATION_V2 [S0, S2]*
- ASSOCIATION_GRP_INFO_V3 [S0, S2]*
- BASIC_V2 [S0, S2]*
- SWITCH_BINARY_V2 [S0, S2]*
- CONFIGURATION_V4 [S0, S2]*
- DEVICE_RESET_LOCALLY_V1 [S0, S2]*
- FIRMWARE_UPDATE_MD_V5 [S0, S2]*
- INDICATOR_V3 [S0, S2]*
- MANUFACTURER_SPECIFIC_V2 [S0, S2]*
- MULTI_CHANNEL_ASSOCIATION_V3 [S0, S2]*
- NOTIFICATION_V8 [S0, S2]*
- POWERLEVEL_V1 [S0, S2]*
- SECURITY_V1
- SECURITY_2_V1
- SUPERVISION_V1
- TRANSPORT_SERVICE_V2
- VERSION_V3 [S0, S2]*
- ZWAVEPLUS_INFO_V2
Z-Wave® Notifications Command Class
| Comment | Overheat Detected |
|---|---|
| Z-Wave Notification Type Name | Heat Alarm |
| Z-Wave Notification Type - Value | 0x04 |
| Z-Wave Notification Type - Event | State |
| Z-Wave Notification Name | Overheat detected |
| Z-Wave Notification Name - Value | 0x02 |
| Z-Wave Notification Name - Version | V2 |
| Z-Wave Device specific | Yes |
| LED signalisation | See LED signalisation table |
| Device reaction – Switch OFF all outputs and send notification | Yes |
| Action to restore – Power cycle | Yes |
| Action to restore – Short press on S button | Yes |
| Action to restore – Press any switch/push-button connected to SW (SW, SW1, SW2, ...) | Yes |
Z-Wave® Associations
Associations enable direct communication between devices without needing the gateway.
- Max. 9 associated devices per group (fixed).
- Recommended: ≤5 per group to avoid delays.
- "Lifeline group" reserved for controllers and devices interpreting reports.
Association Group 1 – Lifeline
Root device: Sends notifications/reports to controlling device.
- INDICATOR_REPORT: LED status
- DEVICE_RESET_LOCALLY_NOTIFICATION: Triggered on request
- SWITCH_BINARY_REPORT: Status change for O (O1)
- NOTIFICATION_REPORT: Triggered on Overheat
Association Group 2
Assigned to SW (SW1) terminal (uses BASIC command class). Triggers on SW (SW1) state.
- Command Class: BASIC_SET (ON/OFF)
- Sends ON/OFF command to associated devices based on SW input
Association Group 3
Assigned to SW (SW1) terminal (uses SWITCH_MULTILEVEL command class). Best suited for push-buttons.
- Command Classes:
- SWITCH_MULTILEVEL_START_LEVEL_CHANGE: Start transition (dimmer, shutter, etc.)
- SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE: Stop ongoing transition
Z-Wave® Important Disclaimer
Z-Wave® wireless communication may not be 100% reliable. Do not use this device in life-critical or high-value scenarios. If the device isn't recognized or appears incorrectly, manually adjust the device type and ensure your gateway supports Z-Wave Plus™ multi-level devices.
Troubleshooting
For troubleshooting, visit our support portal: Support
Compatibility
| Gateway | On/Off | SW On/Off | Notes |
|---|---|---|---|
| Home Assistant | ✅ | ✅ | |
| Fibaro HC 3 / Z-Wave engine 3 | ✅ | ✅ | |
| Homey | ✅ | ✅ | |
| Homee Cube Gen 7 | ✅ | ✅ | |
| Homee Cube Gen 5 | ✅ | ⚪ | |
| Smart Things | ✅ | ✅ | With Shelly Wave edge driver |
| Vera Ezlo | ✅ | ✅ | |
| Cozify | ✅ | ✅ |
Legend:
- ✅ Working / Possible
- ⚪ Partially
- ❌ Not Working / Not Possible
- N/T: Not Tested
- TBD: To be done
Function Meaning / Tested
| Function | Meaning / Tested |
|---|---|
| On/Off | Responds to app UI On/Off command |
| SW On/Off | Reports On/Off changes via SW input |
| Dimming | Responds to app UI dimming command |
| SW Dimming | Reports dimming state changes via SW input |
| Watts | Reports watts unsolicited |
| kWh | Reports kWh unsolicited |
| Up/Down | Responds to app UI Up/Down command |
| SW Up/Down | Reports Up/Down changes via SW input |
| Slats | Slats respond to app UI command |
| SW Slats | Slats report changes made by SW |
| D control | Detached mode: reports scene commands (single/double press, etc.) |
| D Binary | Detached mode: reports binary On/Off via SW input |
| Sensor # | Sensor reported in gateway; note type |
Gateway Guides
Useful guides available in the Shelly Knowledge Base.
Compliance
- Wave 1 Mini multilingual EU Declaration of Conformity (2025-07-22)
- Wave 1 Mini UK PSTI ACT Statement of Compliance