Shelly Wave Shutter
Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

Device: Wave Shutter
- EU Part number / Ordering Code: QNSH-001P10EU
- Z-Wave Product type ID: 0x0003
- Z-Wave Product ID: 0x0082
- Z-Wave Manufacturer: Shelly Europe Ltd.
- Z-Wave Manufacturer ID: 0x0460
Terminology
- Device – In this document, the term “Device” refers to the Shelly Qubino device that is the subject of this guide.
- Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
- S button – The Z-Wave® Service button, located on Z-Wave® devices and used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
- Adding/Inclusion – The process of adding a Z-Wave device to a Z-Wave network (gateway). Words like included, added, etc., are used in this regard.
- Removing/Exclusion – The process of removing a Z-Wave device from a Z-Wave network (gateway). Words like excluded, removed, etc., are used in this regard.
- Blind – Refers to any kind of window treatment, such as venetian blinds, roller blinds (screens), roller shutters, vertical window blinds, curtains, integral venetian blinds, pleated blinds, awnings, etc. Additionally, Wave Shutter can also control window motors, projector screens, or any type of bi-directional AC motor.
Short Description
The Device enables remote control of motorised blinds, roller shutters, venetian blinds, awnings, etc. It measures power consumption of the connected device.
It is recommended to use only motors for blinds with electronic or mechanical limit switches. Motor limit switches must be set correctly before connecting the Device to the motor.
Manual Operation for Shutter
Click here to expand the details of the manual operational instructions
Manual operation for Shutter with momentary switch
Parameter No. 71 set to 0
Parameter No. 1 set to 0
Pressing the push-button connected to SW1 (up) for less than 0.5 second (short press) will initiate upward movement.
Pressing the push-button connected to SW2 (down) for less than 0.5 second (short press) will initiate downward movement.
If the Shutter is moving, any press (on any push-button) will stop the movement.
Pressing the push-button connected to SW1 (up) for more than 0.5 second (long press) will initiate upward movement until the push-button is released.
Pressing the push-button connected to SW2 (down) for more than 0.5 second (long press) will initiate downward movement until the push-button is released.
| Action on push-button | Blind is not moving | Blind is moving up | Blind is moving down | Tilting the slats of venetian blind is ongoing |
|---|---|---|---|---|
| Short press (< 0.5 s) in UP direction | Starts moving the blind upwards | Stops moving the blind | Stops moving the blind | No action |
| Short press (< 0.5 s) in DOWN direction | Starts moving the blind downwards | Stops moving the blind | Stops moving the blind | No action |
| Press and hold (> 0.5 s) in UP direction | Starts moving the blind upwards. In case of venetian blinds, this also includes tilting the slats. | Moving | Moving | Tilting the slats to the end and then moving the blind UP |
| Press and hold (> 0.5 s) in DOWN direction | Starts moving the blind downwards. In case of venetian blinds, this also includes tilting the slats. | Moving | Moving | Tilting the slats to the end and then moving the blind DOWN |
| Release the push-button after a long press | No action | Stops moving the blind | Stops moving the blind | Stops tilting the slats |
Manual operation for Shutter with a toggle switch
Parameter No. 71 set to 0
Parameter No. 1 set to 1
Pressing the toggle switch connected to SW1 (up) will initiate upward movement until the toggle switch is released.
Pressing the toggle switch connected to SW2 (down) will initiate downward movement until the toggle switch is released.
Manual operation for venetian blinds with a momentary switch
- Parameter No. 71 set to 1
- Parameter No. 1 set to 0
General rules:
Short press (< 0.5 seconds) initiates the blind movement
Long press (> 0.5 seconds) initiates the slats movement
Pressing the push-button connected to SW1 (up) for less than 0.5 second (short press) will initiate upward movement.
Pressing the push-button connected to SW2 (down) for less than 0.5 second (short press) will initiate downward movement.
If the Shutter is moving, any press (on any push-button) will stop the movement.
Pressing the push-button connected to SW1 (up) for more than 0.5 second (long press) will initiate slats rotation (0 to 100%) until the push-button is released or the end rotation position is reached. The rotation time is defined in Parameter No. 72.
Pressing the push-button connected to SW2 (down) for more than 0.5 second (long press) will initiate slats rotation (100 to 0%) until the push-button is released or the end rotation position is reached. The rotation time is defined in Parameter No. 72.
| Action on push button | Blind is not moving | Blind is moving up | Blind is moving down | Tilting the slats of venetian blind is ongoing |
|---|---|---|---|---|
| Short press (< 0.5 s) in UP direction | Starts moving the blind upwards | Stops moving the blind | Stops moving the blind | Stops tilting the slats |
| Short press (< 0.5 s) in DOWN direction | Starts moving the blind downwards | Stops moving the blind | Stops moving the blind | Stops tilting the slats |
| Press and hold (> 0.5 s) in UP direction | Starts tilting the slats | No action | No action | Tilting the slats until the rotation is complete |
| Press and hold (> 0.5 s) in DOWN direction | Starts tilting the slats | No action | No action | Tilting the slats until the rotation is complete |
| Release the button after long press | No action | Stops moving the blind | Stops moving the blind | Stops tilting the slats |
Manual operation for venetian blinds with a toggle switch
Parameter No. 71 set to 1
Parameter No. 1 set to 1
Pressing a toggle switch connected to SW1 (up) will initiate upward movement until the toggle switch is released.
Pressing a toggle switch connected to SW2 (down) will initiate downward movement until the toggle switch is released.
When the slats are at 100% position and the UP is pressed quickly, the blind will move up.
When the slats are at 0% position and the DOWN is pressed quickly, the blind will move down.
Slats Positioning
To reach maximum precision of slats positioning when the blind is stopped by a push-button, gateway, or controlled by a gateway, the slats perform additional movement:
- When the slats are set in any intermediate position and receive a command for a different position, the slats always move to the 100% position first and then back to the set position.
- When the blind is moving DOWN, the slats are at 0% position. When the limit switch is reached, or the blind is stopped by a push-button or gateway, the slats rotate to 100% and then move to the previous position (same as before the movement started).
- When the blind is moving UP, the slats are at 100% position. When the blind is stopped by a push-button or gateway, the slats rotate to the previous position (same as before the movement started).
Main Applications
- Residential
- MDU (Multi Dwelling Units – apartments, condominiums, hotels, etc.)
- Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
- Government/municipal
- University/college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave. This means Shelly Qubino Wave works with all certified gateways supporting the Z-Wave communication protocol.
To ensure full functionality, we regularly test compatibility with different Z-Wave gateways.
Simplified Internal Schematics

Device Electrical Interfaces
Inputs
- 2 switch/button inputs on screw terminals
- 3 power supply inputs on screw terminals: N and L
Outputs
- 2 relay outputs with power measurement on screw terminals
Connectivity
Z-Wave – Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety Features
- Over-load detection
- Overheat detection
Supported Load Types
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User Interface
S Button and Operating Modes
- Normal mode
- Setting in progress mode
- Setting mode (with S button)
- Settings mode is required to start procedures like adding (inclusion), removing (exclusion), or factory reset.
- It has a limited time of operation. After completion, the device automatically returns to Normal mode.
- Entering Setting mode:
- Quickly press and hold the S button until the LED turns solid blue.
- An additional quick press changes the menu in an infinite loop.
- Menu LED status has a timeout of 10 seconds before returning to Normal state.
S Button’s Functions
- Manually add the device to a Z-Wave network
- Manually remove the device from a Z-Wave network
- Factory reset the device
Functionality
Automatic calibration is a process during which the device learns the position of the limit switches.
Note! For correct position operation, the device must perform a calibration procedure!
Note! The motor must be equipped with electronic or mechanical limit switches, and the limit positions must be set correctly before calibration.
Shutter Positioning Calibration (Shutter Mode)
- Parameter No. 71 set to 0
Calibration with the Gateway
- 3 → default setting (after factory reset) – Parameter 78
- 1 → start calibration
- 2 → device is calibrated
- 3 → device is not calibrated
- 4 → calibration error
Start calibration:
- Add the device to the Z-Wave network according to inclusion instructions.
- Set Parameter No. 78 (forced Shutter calibration) to 1.
- The device performs the calibration process: full cycle – up, down, up, and down to 50%.
- Check Parameter No. 78 to confirm successful calibration (value = 2).
- Ensure the yellow LED is not blinking.
Note! If values 3 or 4 appear, check if the device completes the full cycle (up, down, up, down to 50%), if limit switches are correctly set, and if wiring follows the user guide.
Calibration with the Push-Button (SW1)
- Move the blind to the top (upper) position.
- Press SW1 four times within 3 seconds.
- The device starts calibration and completes 4 cycles: up, down, up, down to 50%.
- Calibration using SW1 is not time-limited.
Calibration with the S Button
- Enter Setting mode by pressing the S button for less than 0.5 s (short press).
- Keep pressing the S button until the calibration option is selected (yellow LED).
- Start calibration by pressing the S button for more than 2 seconds.
- Confirm the yellow LED is not blinking.
Note! If the yellow LED is still blinking, verify the device completes the full cycle (up, down, up, down to 50%), limit switches are properly set, and wiring matches the user guide.
Slats Tilting Position Calibration (Venetian Mode)
- Parameter No. 71 set to 1
When enabling “venetian blind” mode, slats tilting position calibration must be performed. After that, the position and angle of the slats can be set. By default, rotation time is set to 1.5 s (adjustable via Parameter No. 72).
- Add and perform device calibration as described in the 'Shutter positioning calibration' section.
- Set Parameter No. 71 to 1 ("Venetian blinds").
- Adjust Parameter No. 72:
- If the blind starts moving up/down after slats complete a full cycle → decrease time.
- If slats don’t turn fully → increase time.
- Repeat step 3 until slats position is correct.
Note! If turning time is correct, slats setting should not move the blind up or down.
LED Signalisation
Click to see LED signalisation
General Rules
- Press S button once to switch between Normal and Setting modes.
- Solid LED means the device is in Setting mode (not applicable to plugs). Automatically returns to Normal mode after 10 seconds.
- If not in Alarm mode, LED turns off after 30 minutes (not applicable to plugs). Press S button or power cycle wakes it up for 30 minutes.
Normal Mode LED Status
Removed/Excluded / Not Calibrated
- LED blinks blue for 10 minutes after every power cycle and 10 minutes after S button press.

Removed/Excluded / Calibrated
- LED blinks blue and yellow for 30 minutes after every power cycle and 10 minutes after S button press.

Added/Included / Not Calibrated
- LED blinks green for 10 minutes after every power cycle and 10 minutes after S button press.

Added/Included / Calibrated
- LED blinks green and yellow for 30 minutes after every power cycle and 10 minutes after S button press.

Settings in Progress
Factory Reset and Reboot
- During factory reset: LED turns solid green (~1 sec), then blue and red blink rapidly (0.1s On/Off) for ~2 seconds.
Adding / Removing
- During adding/removing: LED blinks blue in Mode 2.

Shutter Calibration
- During calibration: LED blinks yellow in Mode 2.

Settings Mode with S Button
Adding / Removing Menu Selected
- LED stays solid blue for max 10 seconds.
Adding / Removing – While Pressing S Button
- LED blinks blue in Mode 3.

Factory Reset Menu Selected
- LED stays solid red for max 10 seconds.
Factory Reset – While Pressing S Button
- LED blinks red in Mode 3.

Calibration Menu Selected
- LED stays solid yellow for max 10 seconds.
Calibration – While Pressing S Button
- LED blinks yellow in Mode 3.

Alarm Mode
Over-current Detected
- LED blinks red in Mode 4: 1x (0.2s On / 0.2s Off) + 2s Off, repeating.

Overheat Detected
- LED blinks red in Mode 4: 2x (0.2s On / 0.2s Off) + 2s Off, repeating.

Power Supply Fault
- LED blinks red in Mode 4: 3x (0.2s On / 0.2s Off) + 2s Off, repeating.

LED Blinking Modes
Click to see the LED blinking modes
| Mode | Blink Pattern |
|---|---|
| Mode 1 | 0.5s On / 2s Off |
| Mode 2 | 0.5s On / 0.5s Off |
| Mode 3 | 0.1s On / 0.1s Off |
| Mode 4 | (1x to 6x – 0.2s On / 0.2s Off) + 2s Off |
| Mode 5 | 0.2s On blue / 0.2s On red |
Specifications
| Feature | Value |
|---|---|
| Power supply | 110–240 V AC ±10% |
| Power consumption | < 0.3 W |
| Power measurement [W] | Yes |
| Max switching voltage AC | 240 V |
| Max switching current AC | 10 A per channel |
| Overheating protection | Yes |
| Overload protection | Yes |
| Distance | Up to 40 m indoors (131 ft.) (depends on local conditions) |
| Z-Wave® repeater | Yes |
| CPU | Z-Wave® S800 |
| Z-Wave® frequency band | 868.4 MHz |
| Max RF power transmitted | < 25 mW |
| Size (H x W x D) | 37 x 42 x 16 ±0.5 mm / 1.46 x 1.65 x 0.63 ±0.02 in |
| Weight | 29g |
| Mounting | Wall console |
| Screw terminals max torque | 0.4 Nm / 3.5 lbin |
| Conductor cross section | 0.5 to 1.5 mm² / 20 to 16 AWG |
| Conductor stripped length | 5 to 6 mm / 0.20 to 0.24 in |
| Shell material | Plastic |
| Color | Black |
| Ambient temperature | -20°C to 40°C / -5°F to 105°F |
| Humidity | 30% to 70% RH |
| Max altitude | 2000 m / 6562 ft. |
Basic Wiring Diagram





Legend
| Terminal | Description | Wire | Description |
|---|---|---|---|
| N | Neutral terminal | N | Neutral wire |
| L | Live terminal (110–240 V AC) | L | Live (110–240 V AC) wire |
| O1 | Output terminal for motor UP (open) | — | — |
| O2 | Output terminal for motor DOWN (close) | — | — |
| SW1 | Input terminal for switch/push-button UP (open) | — | — |
| SW2 | Input terminal for switch/push-button DOWN (close) | — | — |
About Z-Wave
Adding the Device to a Z-Wave® Network (Inclusion)
Note! The blind connected to the device will move 2s up/2s down if the device is successfully added/removed from a Z-Wave® network.
Note! In case of Security 2 (S2) inclusion, a dialog will prompt you to enter the 5-digit PIN code printed on the Z-Wave® DSK label on the device and in packaging.
IMPORTANT: Do not lose the PIN code.
SmartStart Inclusion
SmartStart-enabled products can be added by scanning the QR code on the device with a gateway supporting SmartStart. No further action needed.
- Scan the QR code on the device label with the gateway app.
- Add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list.
- Connect the device to power.
- Check if the blue LED is blinking slowly. If yes, it's not added yet.
- Adding starts automatically within seconds.
- LED blinks faster during addition.
- Green LED blinks slowly if successfully added.
Adding with the S Button
- Connect device to power.
- Check if blue LED blinks slowly (not added).
- Enable add/remove mode on gateway.
- Press and hold S button until LED turns solid blue.
- Release, then press and hold (>2s) until blue LED blinks slowly. Releasing starts Learn mode.
- LED blinks faster during addition.
- Green LED blinks slowly if success.
Note! In Setting mode, timeout is 10 seconds before returning to Normal mode.
Adding with a Switch/Push-Button
- Connect device to power.
- Check if blue LED blinks slowly.
- Enable add/remove mode on gateway.
- Toggle the switch/push-button connected to any SW terminal 3 times within 3 seconds (must receive 3 on/off signals).
- LED blinks faster during addition.
- Green LED blinks slowly if success.
Learn mode – State allowing device to receive network info from gateway.
Removing the Device from a Z-Wave® Network (Exclusion)
Note! The device will be removed from your Z-Wave® network, but custom configurations are preserved.
Note! The blind will move 2s up/2s down upon successful removal.
Removing with the S Button
- Connect device to power.
- Check if green LED blinks slowly (added).
- Enable add/remove mode on gateway.
- Press and hold S button until LED turns solid blue.
- Release, then press and hold (>2s) until blue LED blinks slowly. Releasing starts Learn mode.
- LED blinks faster during removal.
- Blue LED blinks slower if success.
Note! Timeout: 10 seconds in Setting mode.
Removing with a Switch/Push-Button
- Connect device to power.
- Check if green LED blinks slowly.
- Enable add/remove mode on gateway.
- Toggle switch/push-button 3 times within 3 seconds.
- LED blinks faster during removal.
- Blue LED blinks slower if success.
Factory Reset
General
After reset, all custom parameters, kWh data, associations, routing, etc., return to defaults. HOME ID and NODE ID are deleted. Use only if gateway is missing or inoperable.
With S Button
- Press and hold S button until LED turns solid blue.
- Press S button multiple times until LED turns solid red.
- Press and hold (>2s) S button until red LED blinks faster. Releasing starts reset.
- During reset: LED turns solid green (~1s), then blue and red blink rapidly (~2s).
- Blue LED blinks slower if successful.
With Switch/Push-Button
Note! Only possible within first minute after power-up.
- Connect device to power.
- Toggle switch/push-button 5 times within 3 seconds.
- During reset: LED turns solid green (~1s), then blue and red blink rapidly (~2s).
- Blue LED blinks slower if successful.
Z-Wave Security and Device Specific Key (DSK)
The device supports Security 2 (S2) using Strong AES 128 Encryption, making Z-Wave the most secure IoT platform.
- Authenticated Control
- Out-of-band DSK for inclusion
- Compatible with most implementations
The device supports:
- S2 Authenticated
- S2 Unauthenticated
- Unsecure inclusion
Note! When adding via S2-enabled gateway, the 5-digit PIN from the DSK label is required. The DSK is printed on the side of the device and in packaging. Do not remove the label.

The first five digits are highlighted/underlined. The DSK is also represented as a QR code.
Obfuscation: Joining node sets bytes 1–2 to 0x00 before sending public key via RF.
DSK usage: Can be used for out-of-band (OOB) authentication. Gateway can scan the QR code and match with obfuscated public key received via RF.
Z-Wave Parameters
Unable to render
{include}
The included page could not be found.
Z-Wave Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO_V2COMMAND_CLASS_SWITCH_MULTILEVEL_V4COMMAND_CLASS_ASSOCIATION_3COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3COMMAND_CLASS_NOTIFICATION_V9COMMAND_CLASS_TRANSPORT_SERVICE_V2COMMAND_CLASS_VERSION_V3COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1COMMAND_CLASS_INDICATOR_V4COMMAND_CLASS_POWERLEVEL_V1COMMAND_CLASS_SECURITY_V1COMMAND_CLASS_SECURITY_2_V1COMMAND_CLASS_MULTI_CHANNEL_V4COMMAND_CLASS_SUPERVISION_V2COMMAND_CLASS_FIRMWARE_UPDATE_MD_V7COMMAND_CLASS_CONFIGURATION_V4COMMAND_CLASS_SWITCH_BINARY_V2COMMAND_CLASS_APPLICATION_STATUS_V2COMMAND_CLASS_METER_V6
Endpoint 1
- Device Class:
- BASIC_TYPE_ROUTING_SLAVE
- GENERIC_TYPE_SWITCH_MULTILEVEL
- SPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL
- Command Classes: All listed above
Endpoint 2
- Device Class: Same as Endpoint 1
- Supported only when Parameter No. 71 = 1
Z-Wave Notifications Command Class
Supported Notifications
- Overload (>1100 W for >5s): Device turns off output and sends notification.
- Overheat (>5s): Device turns off output and sends notification.
| Notification Type | Notification Event |
|---|---|
| Power Management (0x08) | Over-load detected (0x08) |
| Heat alarm (0x04) | Overheat detected (0x02) |
Z-Wave Associations
Associations enable direct communication between devices without gateway involvement.
- Max 9 devices per group (fixed).
- Recommended max 5 per group to avoid delays.
- "Lifeline Group" reserved for gateway only (1 node).
Association Group 1 – Lifeline
- Reports device status.
- Supports:
DEVICE_RESET_LOCALLY_NOTIFICATIONSWITCH_BINARY_REPORT(all outputs)NOTIFICATION_REPORT(Overheat, Overload)METER_REPORT(based on parameters 36, 39)
Group 2 (SW1/SW2, Shutter mode)
- Triggered by SW1/SW2 input
- Supports:
SWITCH_MULTILEVEL_START_LEVEL_CHANGESWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
- Recommended: push buttons
Group 3 (SW1/SW2, Venetian mode)
- Same as Group 2, but for venetian blinds
- Recommended: push buttons
Group 4
- Sends
BASIC_SET ONwhen moving up,OFFwhen moving down - Used to control associated devices
Group 5
- Sends
BASIC_SET OFFwhen reaching top,ONwhen reaching bottom
Groups 6 & 7
- Same as Groups 2 & 3 respectively
Z-Wave Important Disclaimer
Z-Wave wireless communication may not always be 100% reliable. Do not rely solely on this device for life or property safety. If device is unrecognized or misbehaving, manually change device type and ensure gateway supports Z-Wave Plus™ multi-channel devices.
Troubleshooting
For troubleshooting, visit: https://support.shelly.cloud/
Compatibility with Gateways
| Gateway | Up | Down | SW Up | SW Down | W | kWh | Slats | SW Slats | Notes |
|---|---|---|---|---|---|---|---|---|---|
| Home Assistant | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Fibaro HC 3 / Z-Wave engine 3 | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Homey | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Homee Cube Gen 7 | ✅ | ✅ | ✅ | ✅ | ✅ | ❌ | ⚪ | ⚪ | *1 |
| Homee Cube Gen 5 | ✅ | ✅ | ⚪ | ⚪ | ⚪ | ⚪ | ⚪ | ⚪ | *1, *2, *3 |
| Smart Things | ✅ | ✅ | ✅ | ⚪ | ⚪ | ⚪ | With Shelly Wave edge driver *4 | ||
| Vera Ezlo | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Cozify | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ |
Legend:
- ✅ Working / Possible
- ⚪ Partially
- ❌ Not Working / Not Possible
- N/T Not Tested
- TBD To be done
Notes:
- *1 No widget to control slats
- *2 UI reports sent only via buttons; slider doesn’t refresh state
- *3 State refreshed only after stop button press
- *4 Device moves but position not reported
Components and APIs
Depends on the gateway.
Compliance
- Wave Shutter multilingual EU Declaration of Conformity 2025-07-22
- Wave Shutter UK PSTI ACT Statement of Compliance
- Compliance Archive