Shelly Wave 2PM
Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

Device Identification
- Device name: Wave 2PM
- EU Part number/Ordering Code: QNSW-002P16EU
- Z-Wave Product type ID: 0x0002
- Z-Wave Product ID: 0x0081
- Z-Wave Manufacturer: Shelly Europe Ltd.
- Z-Wave Manufacturer ID: 0x0460
Terminology
- Device – In this document, the term “Device” is used to refer to the Wave 2PM device.
- Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
- S button – The Z-Wave® Service button, which is located on Z-Wave® devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
Short Description
The Wave 2PM (Device) is a single product that enables remote control of two electrical devices such as bulbs, ceiling fans, and IR heaters. It switches (on/off) two independent loads and measures their power consumption separately and in total. The Device is compatible with switches (default) and push-buttons.
Switch connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O (O1) to the opposite state – ON, OFF, ON, etc.
- Change switch position once: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association).
Switch connected to input terminal SW2
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O2 to the opposite state – ON, OFF, ON, etc.
- Change switch position once: Change the state of the output state O2 to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association).
Main Applications
- Residential
- MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
- Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
- Government/municipal
- University/college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave.
This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.
To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.
Simplified Internal Schematics

Device Electrical Interfaces
Inputs
- 2 switch/button input on screw terminal
- 3 power supply inputs on screw terminals: N (+) and L (Ʇ)
Outputs
- 2 relay output with power measurement on screw terminal
Connectivity
Z-Wave – Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety Features
Overheat Protection
- Switch off its own relay
- Send Notification Report to the Gateway (Overheat detected)
- LED lights react as specified above (check blinking mode for Overheat detected)
Any of the following activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.
Over-current Protection
Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:
- Switch off its own relay
- Send Notification Report to the Gateway (Over-current detected)
- LED lights react as specified above (check blinking mode for Over-current detected)
Any of the following activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.
Supported Load Types
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User Interface
S Button and Operating Modes
- Normal mode
- Setting in progress mode
- Setting mode (with S button)
- Settings mode is required to start desired procedure (e.g., adding/inclusion, removing/exclusion, factory reset). It has a limited time of operation. After the procedure concludes, the Device automatically returns to Normal mode.
- Entering Setting mode:
- Quickly press and hold the S button until the LED turns solid blue.
- An additional quick press on the S button means menu change in infinite loop.
- Menu LED status has a timeout of 10s before returning to Normal state.
S Button’s Functions
- Manually add the Device to a Z-Wave network
- Manually remove the Device from a Z-Wave network
- Factory Reset the Device
LED Signalisation
Click to see LED signalisation
Normal Mode
Removed/Excluded
The LED will be blinking blue in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.
Added/Included
The LED will be blinking green in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.
Settings in Progress
Factory reset and reboot
During factory reset, the LED will turn solid green for approx. 1 sec, then blue and red LEDs will blink 0.1s On / 0.1s Off for about 2 sec.Adding / Removing
During adding or removing, the LED will be blinking blue in Mode 2.
Firmware updating OTA
During OTA update, the LED will be blinking blue and red in Mode 2.
Checking power supply 230 V AC frequency or 24 V DC voltage
During checking, the LED will be blinking blue and red in Mode 5.
Settings Mode with S Button
Adding / Removing menu selected
When the menu is selected, the LED will be solid blue, for up to 10 seconds.Adding / Removing – while pressing S button – Add/Remove process selected
When the menu is executing, the LED will be blinking blue in Mode 3.
Factory reset menu selected
When the menu is selected, the LED will be solid red, for up to 10 seconds.Factory reset – while pressing S button – Factory reset process selected
When the menu is executing, the LED will be blinking red in Mode 3.
Alarm Mode
Over-current detected
The LED will be blinking red in Mode 4: 1x (0.2s On / 0.2s Off) + 2s Off, repeating.
Overheat detected
The LED will be blinking red in Mode 4: 2x (0.2s On / 0.2s Off) + 2s Off, repeating.
Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)
The LED will be blinking red in Mode 4: 3x (0.2s On / 0.2s Off) + 2s Off, repeating.
LED Blinking Modes
Click to see the LED blinking modes
| Mode | Blinking Pattern |
|---|---|
| Mode 1 | 0.5s On / 2s Off |
| Mode 2 | 0.5s On / 0.5s Off |
| Mode 3 | 0.1s On / 0.1s Off |
| Mode 4 | (1x to 6x: 0.2s On / 0.2s Off) + 2s Off |
| Mode 5 | 0.2s On blue / 0.2s On red |
Specifications
| Feature | Specification |
|---|---|
| Power supply | 110–240 V AC / 24 V DC ±10% |
| Power consumption | < 0.3 W |
| Power measurement [W] | Yes |
| Max switching voltage AC | 240 V |
| Max switching current AC | 10 A per channel, 16 A total, 18 A total peak |
| Max switching voltage DC | 30 V |
| Max switching current DC | 10 A |
| Overheating protection | Yes |
| Over-current protection | Yes |
| Over-voltage protection | Yes |
| Distance | Up to 40 m indoors (131 ft.) (depends on local conditions) |
| Z-Wave® repeater | Yes |
| CPU | Z-Wave® S800 |
| Z-Wave® frequency band | 868.4 MHz |
| Max radio frequency power transmitted | < 25 mW |
| Size (H x W x D) | 37 x 42 x 16 ±0.5 mm / 1.46 x 1.65 x 0.63 ±0.02 in |
| Weight | 29g |
| Mounting | Wall console |
| Screw terminals max torque | 0.4 Nm / 3.5 lbin |
| Conductor cross section | 0.5 to 1.5 mm² / 20 to 16 AWG |
| Conductor stripped length | 5 to 6 mm / 0.20 to 0.24 in |
| Shell material | Plastic |
| Colour | Black |
| Ambient temperature | -20°C to 40°C / -5°F to 105°F |
| Humidity | 30% to 70% RH |
| Max altitude | 2000 m / 6562 ft. |
Basic Wiring Diagram
| Diagram 1 | Diagram 2 |
|---|---|
![]() | ![]() |
| Diagram 3 | Diagram 4 |
|---|---|
![]() | ![]() |
Legend
| Terminals | Description | Wires | Description |
|---|---|---|---|
| N | Neutral terminal | N | Neutral wire |
| L | Live terminal (110–240 V AC) | L | Live (110–240 V AC) wire |
| SW 1 | Switch/push-button input terminal (controlling O1) | + | 24 V DC positive wire |
| SW 2 | Switch/push-button input terminal (controlling O2) | GND | 24 V DC ground wire |
| O1 | Load circuit 1 output terminal | ||
| O2 | Load circuit 2 output terminal | ||
| + | 24 V DC positive terminal | ||
| Ʇ | 24 V DC ground terminal |
About Z-Wave®
Adding the Device to a Z-Wave® Network (Inclusion)
Note! All Device outputs (O, O1, O2, etc.) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-Wave® network.
Note! In case of Security 2 (S2) adding (inclusion), a dialog will appear asking you to enter the corresponding PIN Code (5 underlined digits) written on the Z-Wave® DSK label on the side of the Device and in the packaging.
IMPORTANT: The PIN Code must not be lost.
SmartStart Adding (Inclusion)
SmartStart enabled products can be added into a Z-Wave® network by scanning the QR code on the Device with a gateway providing SmartStart inclusion. No further action is required; the device will be added automatically within 10 minutes of being switched on in the network vicinity.
- With the gateway app, scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list.
- Connect the Device to a power supply.
- Check if the blue LED is blinking slowly. If so, the Device is not added.
- Adding is initiated automatically within seconds after connecting to power.
- The blue LED will blink faster during the adding process.
- The green LED will blink slowly if the Device is successfully added.
Adding (Inclusion) with the S Button
- Connect the Device to a power supply.
- Check if the blue LED is blinking slowly. If so, the Device is not added.
- Enable add/remove mode on the gateway.
- To enter Setting mode, quickly press and hold the S button until the LED turns solid blue.
- Release, then press and hold (>2s) the S button until the blue LED starts blinking slowly. Releasing the button starts Learn mode.
- The blue LED will blink faster during the adding process.
- The green LED will blink slowly if successful.
Note: In Setting mode, the Device has a timeout of 10s before returning to Normal mode.
Adding (Inclusion) with a Switch/Push-button
- Connect the Device to a power supply.
- Check if the blue LED is blinking slowly. If so, the Device is not added.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button connected to any SW terminal (SW, SW1, SW2, etc.) 3 times within 3 seconds (this puts the Device in Learn mode). The Device must receive on/off signal 3 times.
- The blue LED will blink faster during the adding process.
- The green LED will blink slowly if successful.
Learn mode – a state allowing the Device to receive network information from the gateway.
Removing the Device from a Z-Wave® Network (Exclusion)
Note: The Device will be removed from your Z-Wave® network, but any custom configuration parameters will not be erased.
Note! All Device outputs (O, O1, O2, etc.) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-Wave® network.
Removing (Exclusion) with the S Button
- Connect the Device to a power supply.
- Check if the green LED is blinking slowly. If so, the Device is added.
- Enable add/remove mode on the gateway.
- To enter Setting mode, quickly press and hold the S button until the LED turns solid blue.
- Release, then press and hold (>2s) the S button until the blue LED starts blinking slowly. Releasing the button starts Learn mode.
- The blue LED will blink faster during removal.
- The blue LED will blink slower if successful.
Note: In Setting mode, the Device has a timeout of 10s before returning to Normal mode.
Removing (Exclusion) with a Switch/Push-button
- Connect the Device to a power supply.
- Check if the green LED is blinking slowly. If so, the Device is added.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button connected to any SW terminal 3 times within 3 seconds (this puts the Device in Learn mode).
- The blue LED will blink faster during removal.
- The blue LED will blink slower if successful.
Factory Reset
General
After Factory reset, all custom parameters and stored values (kWh, associations, routing, etc.) return to default. HOME ID and NODE ID assigned to the Device will be deleted. Use this only when the gateway is missing or otherwise inoperable.
With the S Button
Note: Factory reset with the S button is possible anytime.
- Press and hold the S button until the LED turns solid blue.
- Press the S button multiple times until the LED turns solid red.
- Press and hold (>2s) the S button until the red LED starts blinking faster. Releasing the button starts the reset.
- During reset, the LED turns solid green for ~1s, then blue and red blink faster for ~2s.
- The blue LED will blink slower if successful.
With a Switch/Push-button
Note: Factory reset with a switch/push-button is only possible within the first minute after power-up.
- Connect the Device to a power supply.
- Toggle the switch/push-button connected to any SW terminal 5 times within 3 seconds.
- During reset, the LED turns solid green for ~1s, then blue and red blink faster for ~2s.
- The blue LED will blink slower if successful.
Remotely via Parameter
Factory reset can be done remotely by setting Parameter No. 120.
Z-Wave® Security and Device Specific Key (DSK)
The Device supports the latest Security 2 (S2) feature. S2 uses strong AES 128 Encryption, making Z-Wave® the most secure IoT platform.
- Authenticated Control
- Out-of-band DSK for inclusion
- May be used by most implementations
The Device supports Security 2 Authenticated, Unauthenticated, and Unsecure adding (inclusion).
Note: When adding the Device to a Z-Wave network with a gateway supporting S2, the PIN Code of the Z-Wave Device Specific Key (DSK) is required. You can find it on the label on the side of the Device and in the packaging. Do not remove the DSK label.

The first five digits of the key are highlighted or underlined to help identify the PIN Code part. The DSK is additionally represented with a QR Code.
DSK Label and QR Code (Example)
Joining node requesting to join the S2 Access Control Class or S2 Authenticated Class will obfuscate its Public Key by setting bytes 1..2 to zeros (0x00) before transferring via RF.
The DSK may be used for out-of-band (OOB) authentication.
- The including gateway may use a QR code scanner to read the entire DSK and match it with the obfuscated public key received via RF.
Z-Wave® Parameters
| Parameter | Description |
|---|---|
| No. 1 – SW (SW1) Switch Type | Defines how the Device treats the switch on SW (SW1). Default: 2 Values: 0 = momentary, 1 = toggle (contact closed=ON), 2 = toggle (device changes status on switch change) |
| No. 2 – SW2 Switch Type | Same as above for SW2. Default: 2 |
| No. 6 – Inputs SW1 & SW2 Swap | Swap operation of SW1 and SW2 without rewiring. Default: 0 (SW1-O1, SW2-O2) Value: 1 → swapped |
| No. 16 – Outputs O1 & O2 Swap | Swap operation of O1 and O2 without rewiring. Default: 0 Value: 1 → reversed |
| No. 17 – Restore O (O1) State After Power Failure | Determines if last state is saved/restored. Default: 0 (save and restore) Value: 1 → remains off |
| No. 18 – Restore O2 State After Power Failure | Same as above for O2. Default: 0 |
| No. 19 – O (O1) Auto OFF with Timer | Schedule automatic OFF after set time. Default: 0 (disabled) Value: 1–32535 seconds/ms (see Param 25) |
| No. 20 – O (O1) Auto ON with Timer | Schedule automatic ON after set time. Default: 0 (disabled) |
| No. 21 – O2 Auto OFF with Timer | Same as above for O2. Default: 0 |
| No. 22 – O2 Auto ON with Timer | Same as above for O2. Default: 0 |
| No. 23 – O (O1) Contact Type (NO/NC) | Relay contact type. Default: 0 (NO) Value: 1 → NC |
| No. 24 – O2 Contact Type (NO/NC) | Same as above for O2. Default: 0 (NO) |
| No. 25 – Set Timer Units for O (O1) | Set timer units: seconds (0) or milliseconds (1). Default: 0 |
| No. 26 – Set Timer Units for O2 | Same as above for O2. Default: 0 |
| No. 36 – O (O1) Power Report on Change (%) | Minimum power change to trigger report. Default: 50 Values: 0 (disabled), 1–100 (%) |
| No. 37 – O2 Power Report on Change (%) | Same as above for O2. Default: 50 |
| No. 39 – Min Time Between Reports (O1) | Minimum interval between reports. Default: 30 Values: 0 (disabled), 1–120s |
| No. 40 – Min Time Between Reports (O2) | Same as above for O2. Default: 30 |
| No. 91 – Water Alarm | Action on water alarm. Default: 0 (no action) Values: 1 → open relay, 2 → close relay |
| No. 92 – Smoke Alarm | Action on smoke alarm. Default: 0 |
| No. 93 – CO Alarm | Action on CO alarm. Default: 0 |
| No. 94 – Heat Alarm | Action on heat alarm. Default: 0 |
| No. 120 – Factory Reset | Reset to factory defaults. Default: 0 (do nothing) Value: 1 → perform reset |
| No. 201–203 – Serial Number Parts | Read-only parts of serial number. Hidden under Advanced tag. |
Z-Wave® Command Classes
- ASSOCIATION_V2 [S0, S2]*
- ASSOCIATION_GRP_INFO_V3 [S0, S2]*
- BASIC_V2 [S0, S2]*
- SWITCH_BINARY_V2 [S0, S2]*
- CONFIGURATION_V4 [S0, S2]*
- DEVICE_RESET_LOCALLY_V1 [S0, S2]*
- FIRMWARE_UPDATE_MD_V5 [S0, S2]*
- INDICATOR_V3 [S0, S2]*
- MANUFACTURER_SPECIFIC_V2 [S0, S2]*
- METER_V6 [S0, S2]*
- MULTI_CHANNEL_V4 [S0, S2]*
- MULTI_CHANNEL_ASSOCIATION_V3 [S0, S2]*
- NOTIFICATION_V8 [S0, S2]*
- POWERLEVEL_V1 [S0, S2]*
- SECURITY_V1
- SECURITY_2_V1
- SUPERVISION_V1
- TRANSPORT_SERVICE_V2
- VERSION_V3 [S0, S2]*
- ZWAVEPLUS_INFO_V2
Endpoint 1
- ASSOCIATION_V2 [S0, S2]*
- ASSOCIATION_GRP_INFO_V3 [S0, S2]*
- BASIC_V2 [S0, S2]*
- SWITCH_BINARY_V2 [S0, S2]*
- METER_V6 [S0, S2]*
- MULTI_CHANNEL_V4 [S0, S2]*
- NOTIFICATION_V8 [S0, S2]*
- SECURITY_V1
- SECURITY_2_V1
- SUPERVISION_V1
- ZWAVEPLUS_INFO_V2
Endpoint 2
- ASSOCIATION_V2 [S0, S2]*
- ASSOCIATION_GRP_INFO_V3 [S0, S2]*
- BASIC_V2 [S0, S2]*
- SWITCH_BINARY_V2 [S0, S2]*
- METER_V6 [S0, S2]*
- MULTI_CHANNEL_V4 [S0, S2]*
- NOTIFICATION_V8 [S0, S2]*
- SECURITY_V1
- SECURITY_2_V1
- SUPERVISION_V1
- ZWAVEPLUS_INFO_V2
Note: [S2] = Security S2 Command Class
Z-Wave® Notifications Command Class
Overheat Detected
| Field | Value |
|---|---|
| Comment | Overheat detected |
| Notification Type Name | Heat Alarm |
| Type Value | 0x04 |
| Event | State |
| Notification Name | Overheat detected |
| Name Value | 0x02 |
| Version | V2 |
| Device Specific | Yes |
| LED Signalisation | See table |
| Device Reaction | Switch OFF all outputs and send notification |
| Restore Actions | Power cycle, short press S button, press any switch |
Over-current Detected (O1, O2, O1+O2)
| Field | Value |
|---|---|
| Comment | Over-current detected |
| Notification Type Name | Power management |
| Type Value | 0x08 |
| Event | State |
| Notification Name | Over-current detected |
| Name Value | 0x06 |
| Version | V3 |
| Device Specific | Yes |
| LED Signalisation | See table |
| Device Reaction | Switch OFF output(s) and send notification |
| Restore Actions | Power cycle, short press S button, press any switch |
AC Mains Disconnected
| Field | Value |
|---|---|
| Comment | AC mains disconnected (valid for AC/DC) |
| Notification Type Name | Power management |
| Type Value | 0x08 |
| Event | State |
| Notification Name | AC mains disconnected |
| Name Value | 0x02 |
| Version | V2 |
| Device Specific | Yes |
| LED Signalisation | See table |
| Device Reaction | Switch OFF all outputs and send notification |
| Restore Actions | Power cycle, short press S button, press any switch |
Z-Wave® Associations
Associations enable direct communication between devices without the gateway.
- Max 9 devices per group (recommended ≤5)
- “Lifeline Group” reserved for gateway only (1 node)
Root Device
Association Group 1 – Lifeline
- INDICATOR_REPORT: LED status
- DEVICE_RESET_LOCALLY_NOTIFICATION: triggered upon request
- SWITCH_BINARY_REPORT: status change for all outputs
- NOTIFICATION_REPORT: Overheat
- NOTIFICATION_REPORT: Over-current (sum)
- NOTIFICATION_REPORT: Over-voltage
- NOTIFICATION_REPORT: AC mains disconnected
- METER_REPORT: power consumption (based on Params 36–43)
Group 2
- Assigned to SW (SW1) terminal (Basic command class)
- Triggered by SW (SW1)
- Sends BASIC_SET ON/OFF to associated device
Group 3
- Assigned to SW (SW1) terminal (Switch Multilevel)
- Supports:
- SWITCH_MULTILEVEL_START_LEVEL_CHANGE
- SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
Recommended: use push buttons
Group 4
- Assigned to SW2 terminal (Basic command class)
- Sends BASIC_SET ON/OFF
Group 5
- Assigned to SW2 terminal (Switch Multilevel)
- Supports same commands as Group 3
Recommended: use push buttons
Endpoint 1
Group 1 – Lifeline
- SWITCH_BINARY_REPORT: O1 status
- NOTIFICATION_REPORT: Over-current detected O1
- METER_REPORT: O1 power consumption
Groups 2 & 3
Same as root device (SW1)
Endpoint 2
Group 1 – Lifeline
- SWITCH_BINARY_REPORT: O2 status
- NOTIFICATION_REPORT: Over-current detected O2
- METER_REPORT: O2 power consumption
Groups 2 & 3
Same as root device (SW2)
Z-Wave® Important Disclaimer
Z-Wave® wireless communication may not always be 100% reliable. This Device should not be used in situations where life and/or valuables depend solely on its functioning. If the Device is not recognized by your gateway, manually change the Device type and ensure your gateway supports Z-Wave Plus™ multi-level devices.
Troubleshooting
For troubleshooting, visit our support portal: https://support.shelly.cloud/
Compatibility with Gateways
| Gateway | On/Off 1 | On/Off 2 | SW 1 On/Off | SW 2 On/Off | W 1 | W 2 | kWh | Notes |
|---|---|---|---|---|---|---|---|---|
| Home Assistant | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Fibaro HC 3 / Z-Wave engine 3 | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Homey | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | Solution |
| Homee Cube Gen 7 | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Homee Cube Gen 5 | P | P | P | P | P | P | P | *1 |
| SmartThings | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | With Shelly Wave edge driver |
| Vera Ezlo | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Cozify | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | ✅ | |
| Hubitat | ⭐ | ⭐ | ⭐ | ⭐ | ⭐ | ⭐ | ⭐ |
*1 – Device configured as single-channel; one switch controls both outputs simultaneously.
Legend
| Symbol | Meaning |
|---|---|
| ✅ | Working / Possible |
| ⭐ | Not Working / Not Possible |
| P | Partially |
| N/T | Not Tested |
| TBD | To be done |
Function Meanings
| Function | Meaning |
|---|---|
| On/Off | Responds to app UI On/Off command |
| SW On/Off | Reports On/Off changes via SW input |
| Dimming | Responds to app UI dimming command |
| SW Dimming | Reports dimming state via SW input |
| Watts | Reports Watts unsolicited |
| kWh | Reports kWh unsolicited |
| Up/Down | Responds to app UI Up/Down command |
| SW Up/Down | Reports Up/Down changes via SW input |
| Slats | Slats respond to app UI command |
| SW Slats | Slats report changes via SW |
| D control | Reports scene commands (single/double press, etc.) in detached mode |
| D Binary | Reports binary On/Off via SW input in detached mode |
| Sensor # | Sensor report visualized in gateway; type in notes |
Gateway Guides
You may find useful guides on gateways in the Z-Wave Shelly Knowledge Base.
Compliance
- Wave 2PM multilingual EU Declaration of Conformity 2025-07-22
- Wave 2PM UK PSTI ACT Statement of Compliance