Skip to content

Shelly Wave Pro 1PM – Device Documentation

Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

Wave-pro1pm-160x350.jpg


Device Identification

  • Device: Wave Pro 1PM
  • AUS Part number / Ordering Code: QPSW-0A1P16AU
  • Z-Wave Product type ID: 0x0002
  • Z-Wave Product ID: 0x008B
  • Z-Wave Manufacturer: Shelly Europe Ltd.
  • Z-Wave Manufacturer ID: 0x0460

Terminology

TermDefinition
DeviceIn this document, the term “Device” refers to the Shelly Qubino device being discussed.
GatewayA Z-Wave® gateway (also called Z-Wave® controller, main controller, primary controller, or hub) that serves as the central hub for a Z-Wave® smart home network.
S buttonThe Z-Wave® Service button located on Z-Wave® devices, used for inclusion, exclusion, and factory reset.

Short Description

The Wave Pro 1PM is a DIN rail-mounted smart switch with power measurement. It controls the on/off function for one electrical load up to 16 A, and supports both switches (default) and push-buttons.

Switch Connected to Input Terminal SW (SW1)

If configured as a switch (default):

  • One toggle: Changes output O (O1) state (on → off, off → on), sends command to associated devices in groups 2 and 3.
  • Two toggles within 500ms: Interpreted as "double press", sends command to dimmers, shutters, etc., in groups 2 and 3.

Switch-Memory Connected to Input Terminal SW (SW1)

If configured as switch-memory:

  • Close contact: Output O (O1) turns ON and sends command to associated devices in groups 2 and 3.
  • Open contact: Output O (O1) turns OFF and sends command to associated devices in groups 2 and 3.

Push-Button Connected to Input Terminal SW (SW1)

If configured as a push-button:

  • Short press: Toggles output O (O1) state (on ↔ off), sends command to groups 2 and 3.
  • Hold: Sends command to group 3.
  • Release: Sends command to group 3.

Switching On/Off Load Connected to O (O1)

The load connected to O (O1) can be switched via:

  • Z-Wave commands
  • Automatic switching (via Parameters No. 19 and 20)
  • Pressing the switch/push-button SW (SW1): toggles load state

Main Applications

  • Residential
  • MDU (Multi Dwelling Units: apartments, condos, hotels)
  • Light commercial (small offices, retail, restaurants, gas stations)
  • Government / Municipal
  • University / College

Integrations

Shelly Wave devices are built on Z-Wave, the world’s leading smart home technology. They work with all certified gateways supporting the Z-Wave protocol.

We regularly test compatibility across various Z-Wave gateways to ensure full feature support.


Simplified Internal Schematics

Shelly Pro 1PM internal schematics


Device Electrical Interfaces

Inputs

  • 2 switch/button inputs on screw terminals
  • 2 power supply inputs on screw terminals: 2 N (+) and 3 L (−)
  • 1 relay input on screw terminal

Outputs

  • 1 relay output with power measurement on screw terminal

Connectivity

  • Z-Wave: Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security

Safety Features

Overheat Protection

  • If temperature exceeds 80°C for more than 5 seconds, the device:
    • Turns off its own relay
    • Sends a Notification Report to the gateway ("Overheat detected")
    • LED reacts accordingly (see LED blinking modes)

Reset conditions:

  • Power cycle
  • Short press on S button
  • Press any switch/push-button on SW (SW1, SW2, etc.)

Note: Overheat protection is always active and cannot be disabled.

More details: Notification for Overheat Detected


Overcurrent Protection

  • If current exceeds 16A + 10% (17.6A) for more than 5 seconds, the device:
    • Turns off its relay
    • Sends a Notification Report ("Over-current detected")
    • LED blinks accordingly

Reset conditions:

  • Power cycle
  • Short press on S button
  • Press any switch/push-button on SW (SW1, SW2, etc.)

Note: Overcurrent protection is always active and cannot be disabled.

More details: Notification for Over-current Detected


Overvoltage Protection

  • Valid for standard 230 V AC supply.
  • If voltage exceeds 278 V AC (240V +15%) for more than 5 seconds, the device:
    • Turns off its relay
    • Sends a Notification Report ("Overvoltage detected")
    • LED blinks accordingly

Reset conditions:

  • Power cycle
  • Short press on S button
  • Press any switch/push-button on SW (SW1, SW2, etc.)

Note: Overvoltage protection is always active and cannot be disabled.

More details: Notification for Overvoltage Detected


Supported Load Types

  • Resistive (incandescent bulbs, heating devices)
  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)
  • Inductive with RC Snubber (LED drivers, transformers, fans, refrigerators, air conditioners)

User Interface

S Button and Operating Modes

  1. Normal mode
  2. Setting in progress mode
  3. Setting mode (with S button)
    • Used for inclusion, exclusion, factory reset, etc.
    • Limited duration; automatically reverts to Normal mode after procedure.

Entering Setting Mode:

  • Quickly press and hold the S button until the LED turns solid blue.
  • Additional quick press → cycles through menu options.
  • Menu timeout: 10 seconds before returning to Normal mode.

S Button Functions

  • Manually add device to Z-Wave network
  • Manually remove device from Z-Wave network
  • Factory reset device

LED Signalisation

ModeStatusMeaning
Mode 10.5s On / 2s OffNormal operation (blue = excluded, green = included)
Mode 20.5s On / 0.5s OffAdding/removing, OTA update, power check
Mode 30.1s On / 0.1s OffExecuting action (add/remove/factory reset)
Mode 4(1–7 times) 0.2s On/Off + 2s OffAlarm states (overcurrent, overheat, overvoltage, etc.)
Mode 50.2s On blue / 0.2s On redPower supply check (AC frequency or DC voltage)

Alarm LED Patterns:

AlarmPatternDescription
Overcurrent detected1x: 0.2s On / 0.2s Off, 2s OffRepeats
Overheat detected2x: 0.2s On / 0.2s Off, 2s OffRepeats
Power supply fault3x: 0.2s On / 0.2s Off, 2s OffRepeats
Overvoltage detected7x: 0.2s On / 0.2s Off, 2s OffRepeats

🔔 All alarms trigger relay OFF and send notification to gateway.


Specifications

⚠️ Error rendering macro 'excerpt-include': User does not have permission to view the page 'DEV:Technical Specifications'.


Basic Wiring Diagram

WAVE-PRO1PM-170X300.jpg


Legend

TerminalFunctionWirePurpose
NNeutral terminalNNeutral wire
LLive terminal (110–240 V AC)LLive (110–240 V AC) wire
SW1Switch/push-button input (controls O)Control input
SW2Switch/push-button inputOptional control input
ILoad circuit inputInput side of load
OLoad circuit outputOutput side of load

About Z-Wave®

Adding the Device to a Z-Wave® Network (Inclusion)

⚠️ Note: All outputs (O, O1, etc.) will briefly turn on/off during successful inclusion/exclusion.

SmartStart Inclusion

  1. Scan QR code on device label using gateway app.
  2. Add DSK to provisioning list.
  3. Connect device to power.
  4. Blue LED blinking in Mode 1 → not added.
  5. Auto-inclusion starts within seconds.
  6. Blue LED blinks in Mode 2 during process.
  7. Green LED blinks in Mode 1 if successful.

Adding with S Button

  1. Connect device to power.
  2. Check blue LED blinking in Mode 1.
  3. Enable add/remove mode on gateway.
  4. Press and hold S button until LED turns solid blue.
  5. Release, then press & hold (>2s) until LED blinks in Mode 3 → Learn mode starts.
  6. Blue LED blinks in Mode 2 during adding.
  7. Green LED blinks in Mode 1 if successful.

⏱️ Setting mode timeout: 10 seconds

Adding with Switch/Push-Button

  1. Connect device to power.
  2. Confirm blue LED blinking in Mode 1.
  3. Enable add/remove mode on gateway.
  4. Toggle SW terminal 3 times within 3 seconds → puts device in Learn mode.
  5. Blue LED blinks in Mode 2 during process.
  6. Green LED blinks in Mode 1 if successful.

📌 Learn mode: State allowing device to receive network info from gateway.


Removing the Device from a Z-Wave® Network (Exclusion)

⚠️ Note: Custom settings remain unchanged; only network association is removed.

Removing with S Button

  1. Connect device to power.
  2. Confirm green LED blinking in Mode 1 → device is added.
  3. Enable add/remove mode on gateway.
  4. Press and hold S button until LED turns solid blue.
  5. Release, then press & hold (>2s) until LED blinks in Mode 3 → Learn mode starts.
  6. Blue LED blinks in Mode 2 during removal.
  7. Blue LED blinks in Mode 1 if successful.

⏱️ Setting mode timeout: 10 seconds

Removing with Switch/Push-Button

  1. Connect device to power.
  2. Confirm green LED blinking in Mode 1.
  3. Enable add/remove mode on gateway.
  4. Toggle SW terminal 3 times within 3 seconds → Learn mode.
  5. Blue LED blinks in Mode 2 during removal.
  6. Blue LED blinks in Mode 1 if successful.

Factory Reset

General

After reset, all custom parameters (kWh, associations, routing, etc.) revert to default. HOME ID and NODE ID are deleted.

💡 Use only when gateway is missing or inoperable.

With S Button

  1. Press and hold S button until LED turns solid blue.
  2. Press S button repeatedly until LED turns solid red.
  3. Press and hold (>2s) S button until red LED blinks in Mode 3 → reset begins.
  4. During reset: LED turns solid green (~1s), then blue/red blink in Mode 3 (~2s).
  5. Blue LED blinking in Mode 1 indicates success.

With Switch/Push-Button

⚠️ Only possible within first minute after power-up.

  1. Connect device to power.
  2. Toggle SW terminal 5 times within 3 seconds.
  3. LED turns solid green (~1s), then blue/red blink in Mode 3 (~2s).
  4. Blue LED blinking in Mode 1 indicates success.

Remotely via Parameter No. 120

Set Parameter 120 to 1431655765 (hex 0x55555555) to trigger remote factory reset.

✅ After reset, parameter resets to 0.


Z-Wave® Security and Device Specific Key (DSK)

  • Supports Security 2 (S2) with AES-128 encryption.
  • Requires S2-enabled gateway for full security.
  • Uses Out-of-Band DSK authentication.
  • PIN Code (first 5 digits) required during S2 inclusion.

📌 DSK Label Example:

  • Printed on device side and inside packaging.
  • Include QR code for scanning.
  • Do not remove label.

🔐 Important: Never lose the DSK label.


Z-Wave® Parameters

ParameterDescriptionDefaultValues
1 – SW (SW1) Switch TypeDefines behavior of switch on SW120: momentary, 1: toggle (contact closed=ON), 2: toggle (state changes)
2 – SW2 Switch TypeSame for SW2 terminal20: momentary, 1: toggle (closed=ON), 2: toggle (state changes)
17 – Restore State After Power FailureSave last state after outage?00: yes, 1: no (remains off)
19 – Auto OFF Timer (O1)Schedule auto-off after ON00: disabled, 1–32535: sec or ms (see Param 25)
20 – Auto ON Timer (O1)Schedule auto-on after OFF00: disabled, 1–32535: sec or ms
23 – O (O1) Contact TypeRelay contact: NO or NC00: NO, 1: NC
25 – Timer Units (sec/ms)Set timer resolution00: seconds, 1: milliseconds
36 – Power Report Change (%)Min % change to report power500: disabled, 1–100%
39 – Min Time Between Reports (O1)Min interval between reports300: disabled, 1–120 seconds
91 – Water Alarm ResponseAction on water alarm00: none, 1: open relay, 2: close relay
92 – Smoke Alarm ResponseAction on smoke alarm00: none, 1: open, 2: close
93 – CO Alarm ResponseAction on CO alarm00: none, 1: open, 2: close
94 – Heat Alarm ResponseAction on heat alarm00: none, 1: open, 2: close
120 – Factory ResetTrigger reset00: no, 1431655765 (0x55555555)
201–203 – Serial Number PartsRead-only, hiddenDevice-specific0x00000000 – 0x7FFFFFFF

Z-Wave® Command Classes

ClassSecurity
ASSOCIATION_V2[S0, S2]*
ASSOCIATION_GRP_INFO_V3[S0, S2]*
BASIC_V2[S0, S2]*
SWITCH_BINARY_V2[S0, S2]*
CONFIGURATION_V4[S0, S2]*
DEVICE_RESET_LOCALLY_V1[S0, S2]*
FIRMWARE_UPDATE_MD_V5[S0, S2]*
INDICATOR_V3[S0, S2]*
MANUFACTURER_SPECIFIC_V2[S0, S2]*
METER_V6[S0, S2]*
MULTI_CHANNEL_ASSOCIATION_V3[S0, S2]*
NOTIFICATION_V8[S0, S2]*
POWERLEVEL_V1[S0, S2]*
SECURITY_V1
SECURITY_2_V1
SUPERVISION_V1
TRANSPORT_SERVICE_V2
VERSION_V3[S0, S2]*
ZWAVEPLUS_INFO_V2

[S2] = Security S2 Command Class


Z-Wave® Notifications Command Class

Overheat Detected

FieldValue
Notification Type NameHeat Alarm
Value0x04
EventState
Notification NameOverheat detected
Value0x02
VersionV2
Device SpecificYes
LED SignalisationSee table
Device ReactionTurn off output, send notification
Restore ActionPower cycle, S button press, SW press

Over-current Detected O (O1)

FieldValue
Notification Type NamePower management
Value0x08
EventState
Notification NameOver-current detected
Value0x06
VersionV3
Device SpecificYes
LED SignalisationSee table
Device ReactionTurn off O(1), send notification
Restore ActionPower cycle, S button press, SW press

AC Mains Disconnected

FieldValue
Notification Type NamePower management
Value0x08
EventState
Notification NameAC mains disconnected
Value0x02
VersionV2
Device SpecificYes
LED SignalisationSee table
Device ReactionTurn off all outputs, send notification
Restore ActionPower cycle, S button press, SW press

Z-Wave® Associations

GroupNodesTriggerCommandsNotes
1 (Lifeline)1 (Gateway)Status, errorsINDICATOR_REPORT, DEVICE_RESET_LOCALLY_NOTIFICATION, SWITCH_BINARY_REPORT, NOTIFICATION_REPORT, METER_REPORTStandard lifeline
29SW1 (On/Off)BASIC_SET ON/OFFFor basic switch control
39SW1 (Dimming)SWITCH_MULTILEVEL_START_LEVEL_CHANGE / STOPFor dimmer/slats
49SW1 (On/Off)BASIC_SET ON/OFFDuplicate of group 2
59SW1 (Dimming)SWITCH_MULTILEVEL_START_LEVEL_CHANGE / STOPDuplicate of group 3

Z-Wave® Important Disclaimer

Z-Wave® communication may not be 100% reliable. Do not rely solely on this device for life-critical applications. If the device isn't recognized, manually change the device type and confirm gateway supports Z-Wave Plus™ multi-level devices.


Troubleshooting

For help, visit: Shelly Support Portal


Compatibility with Gateways

GatewayOn/OffSW On/OffWattskWhNotes
Home Assistant
Fibaro HC3 / Z-Wave engine 3
Homey
Homee Cube Gen 7
Homee Cube Gen 5⚠️ P*1⚠️ ★*2⚠️ ★*2*1 UI doesn’t reflect updates
*2 W/kWh not reported
SmartThingsWith Shelly Wave edge driver
Vera Ezlo
Cozify

🔍 Legend:

  • ✅ = Working / Possible
  • ⚠️ ★ = Not working / Not possible
  • ⚠️ P = Partially
  • N/T = Not Tested
  • TBD = To Be Done

Gateway Guides

Useful guides: Shelly Knowledge Base – Z-Wave


Compliance


Printed User Guide

Download PDF: Wave_Pro1PM_multilang_2023_print_V1.pdf